RFAV Serisi soğutucuların teknik verileri
|
|
MODEL |
RFA
|
*9
|
*15
|
C25
|
C35
|
C50/Z
|
C60/Z
|
C70/Z
|
C95/Z
|
C115/Z
|
C155/Z
|
C190/Z
|
C230/Z
|
C310/Z
|
C380/Z
|
C460/Z
|
C590/Z
|
C720/Z
|
|
RFAV
|
9
|
15
|
25
|
35
|
50/Z
|
60/Z
|
70/Z
|
95/Z
|
115/Z
|
155/Z
|
190/Z
|
230/Z
|
310/Z
|
380/Z
|
460/Z
|
590/Z
|
720/Z
|
Soğutma
kapasitesi |
**kW
**kcal/h
|
8,8
7.600
|
15,1
13.100
|
24,9
21.500
|
33,4
28.700
|
47,4
40.800
|
57,9
49.800
|
66,8
57.400
|
94,8
81.700
|
116
99.600
|
155
133.000
|
190
163.000
|
232
199.000
|
310
266.000
|
380
326.000
|
464
398.000
|
588
506.000
|
718
617.000
|
|
Kompresör
|
n°
nom.kW
maks.kW
|
1
1,5
2,7
|
1
2,7
4,7
|
1
4,4
7,4
|
1
5,8
9,9
|
1
8,5
14
|
1
10,4
17,5
|
2
11,6
19,8
|
2
17
28
|
2
20,8
35
|
2
26,8
45,2
|
2
34
56
|
2
41,6
70
|
4
53,8
91
|
4
68
112
|
4
83,2
140
|
4
120,8
170
|
4
140
198
|
|
Verim |
kW/kW
|
5,9
|
5,6
|
5,7
|
5,8
|
5,6
|
5,6
|
5,8
|
5,6
|
5,6
|
5,8
|
5,6
|
5,6
|
5,8
|
5,6
|
5,6
|
4,9
|
5,1
|
|
Pompa "c" |
kW
lt/dak
bar
|
0,55
26
3,2
|
0,65
44
3,1
|
0,95
72
3,3
|
1,1
96
3
|
1,3
139
3,2
|
1,4
165
3,1
|
1,8
192
3,4
|
2,1
277
3,1
|
3,2
330
3,6
|
3,7
443
3,4
|
5,2
553
3,6
|
6
660
3,5
|
6,5
886
3,2
|
7
1.107
3,2
|
9,5
1.320
3,1
|
10,2
1.687
2,7
|
14
2.060
3,2
|
|
Pompa "v" |
kW
lt/dak
bar
|
0,32
26
2,1
|
0,37
44
2
|
0,45
72
2
|
0,52
96
1,9
|
0,55 139
1,5
|
0,6
165
1,7
|
0,75
192
1,6
|
1,3
277
1,9
|
1,3
330
1,7
|
2
443
1,9
|
2,5
553
1,8
|
2,6
660
1,7
|
3,5
886
1,7
|
3,7
1.107
1,5
|
5
1.320
1,5
|
7,5
1.687
1,8
|
7,5
2.060
1,6
|
|
Vantilatör |
n°
kW
m3/h
|
1
0,8
4.900
|
1
0,7
6.600
|
1
1,3
15.500
|
1
1,3
14.300
|
1
1,3
16.500
|
1
1,3
18.500
|
1
1,3
18.000
|
2
2,7
34.000
|
2
2,7
32.000
|
3
3,9
47.000
|
3
3,9
53.000
|
4
5,2
72.000
|
6
7,8
110.000
|
6
7,8
106.000
|
8
10,4
144.000
|
10
13,5
166.000
|
10
18
218.000
|
|
Gürültü
10m. |
dB (A)
|
51
|
51
|
53
|
53
|
54
|
54
|
55
|
55
|
55
|
56
|
57
|
58
|
59
|
59
|
60
|
60
|
60
|
|
Kapasite
"c" |
lt
|
50
|
50
|
120
|
120
|
180
|
250
|
250
|
400
|
400
|
600
|
600
|
800
|
1.200
|
1.200
|
2.000
|
2.000
|
3.000
|
Net
ağırlık"c"
Net ağırlık"v" |
kg
kg
|
110
110
|
210
210
|
330
330
|
350
350
|
520
490
|
590
550
|
850
810
|
970
970
|
1.000
1.000
|
1.600
1.400
|
1.700
1.500
|
2.200
1.700
|
3.300
3.150
|
3.800
3.200
|
2.000
5.100
|
5.400
4.500
|
6.300
5.200
|
|
Boru çapı |
"
|
3/4
|
1
|
1 1/4
|
1 1/4
|
1 1/2
|
1 1/2
|
2
|
2
|
2 1/2
|
2 1/2
|
2 1/2
|
3
|
3
|
4
|
4
|
4
|
5
|
|
Uzunluk |
mm
|
650
|
650
|
900
|
900
|
1.750
|
2.010
|
2.010
|
2.870
|
2.870
|
3.730
|
3.750
|
5.240
|
4.700
|
4.700
|
6.420
|
6.420
|
7.800
|
|
Derinlik |
mm
|
800
|
800
|
1.520
|
1.520
|
1.120
|
1.250
|
1.250
|
1.250
|
1.250
|
1.250
|
1.400
|
1.400
|
2.220
|
2.220
|
2.200
|
2.200
|
2.200
|
|
Yükseklik |
mm
|
1.100
|
1.100
|
1.680
|
1.680
|
2.000
|
2.000
|
2.000
|
2.000
|
2.000
|
2.000
|
2.110
|
2.110
|
2.110
|
2.110
|
2.110
|
2.110
|
2.310
|
* Atmosferik
depolu tipler (modüler değil).
** Soğutma kapasitesi +25 °C ortam sıcaklığında ve +15 °C su
sıcaklığında(%30 glikol karışımlı) iken hesaplanmıştır.
|
|
The water Thermo-cooling Units
of the “GTW” range
are monobloc units consisting of a water condensed cooling section and a
thermoregulating section in single-zone or double-zone (Duplex)
version.They are especially suitable for cooling moulds of plastics
injection machines and any other industrial process requiring temperature
control with temperature ranging from –5 to +90°C. Key features:
Cooling section:
• R407C ecological refrigerant
• Scroll rotating
motor-compressor groups that has a coefficient of performance (COP) equal
to 6
• Stainless steel brazed plate
condenser that has a high-coefficient water-gas exchange
• Molecular sieves dehydrating
filter
• Liquid level sightglass
• Solenoid valve
• Expansion valve
• Flow switch for water flow
control
• Safety pressure switches for
high and low gas pressure
• Water level pressure switch
• Plate evaporator thet has a
high-coefficient of water-gas exchange
• Shock absorbers to limit the
transmission of vibrations generated by compressors
• Water re-circulating
centrifugal electro-pump fitted with a non return valve
• Manual by-pass valve, or in
alternative automatic proportional by-pass valve if required
• Built-in reservoir
• Water fill-up group
• A microprocessor based
electronic instrumentation for the set-up and display of the working
temperature.
Heating section for each zone
• Heating circuit with armoured
electric heaters with a wide exchange surface
• Heaters powered via
solid-state relays control (greater efficiency, reliability, less noise
and no wear, when compared with to contactors)
• Cooling automatic mixing valve
• Centrifugal electro-pump for
recirculating the water
• Control panel complete with
electronic microprocessor to control the temperature with PID regulation
for both heating and cooling
• RS485 Serial communication
with MODBUS and other protocols (option)
• Energy saving kit (option)
• Painted frame on castors
• Fittings available: on-off
valves, manifolds that have multi delivery/return for machine connections
as well as connection pipes, the latter may be fitted with glass fibre
rubber insulation and protected by a stainless steel sleeve.
The Thermo-cooling Units of the
“GTW” and “GTW-DUPLEX” range can be coupled with special Air Blast
Coolers of the “BR” range so as
a to obtain Economising Cooling Systems of the “BRT” range.
Industrial Frigo long term
experience in the industrial cooling field, has enabled us to design and
manufacture
a wide range of special purpose
built equipment to meet customers specific requirements.
| RANGE |
VERSION |
GAS |
COOLING CAPACITY |
 |
Water thermo-cooling
units by water condensation |
R407C
(ecologicical) |
7,2 - 1.602 kW